!WRITE¶
Enables output to various files (result files, visualization files, logs, and FEMAP neutral files) and specifies the output frequency. In the implementation, this is a single card, and the RESULT / VISUAL / LOG / FEMAP (formerly UTABLE) parameters select the output destinations (in fistr1/src/common/fstr_ctrl_common.f90, fstr_ctrl_get_WRITE; in fistr1/src/lib/m_out.f90, fstr_ctrl_get_output).
Visualization-specific controls such as the visualization format and surface specification are provided on the separate !VISUAL card.
Parameters¶
| Parameter | Role |
|---|---|
RESULT |
Enables analysis result data file output. |
VISUAL |
Enables visualization data output through the in-memory visualizer. |
LOG |
Enables log file output. |
FEMAP |
Enables FEMAP neutral format output. |
FREQUENCY = n |
Specifies the output step interval. The default is 1. |
RESULT / VISUAL / LOG / FEMAP can be specified together on the same card and enabled independently.
Examples¶
!WRITE,RESULT — Result file¶
Enables analysis result data file output. The physical quantities to output are selected with !OUTPUT_RES.
!WRITE,VISUAL — Visualization file¶
Enables visualization data output. A minimal dataset example is shown below. On the !VISUAL card, the surface_num and !surface specifications cannot be omitted.
!WRITE,LOG — Log¶
Specifies the step interval for log file output.
Combined example¶
Multiple output destinations can be enabled simultaneously with a single !WRITE card.